The Great Services added new photo
May 27, 2024 at 01:51 pm —
293 Series Coolant-proof Micrometer

293 Series Coolant-proof Micrometer

Specification  Metric _ With ratchet stop Range Model  Resolution Accuracy 0 - 25mm 293-230-30 / 293-240-30 0.001mm ±1µm 25 - 50mm 293-231-30 / 293-241-30 0.001mm ±1µm 50 - 75mm 293-232-30 / 293-242-30 0.001mm ±1µm 75 - 100mm 293-233-30 / 293-243-30  0.001mm ±2µm 100 - 125mm 293-250-30 0.001mm ±2µm 125 - 150mm 293-251-30 0.001mm ±2µm 150 - 175mm 293-252-30 0.001mm ±3µm 175 - 200mm 293-253-30 0.001mm ±3µm 200 - 225mm 293-254-30 0.001mm ±3µm 225 - 250mm 293-255-30 0.001mm ±4µm 250 - 275mm 293-256-30 0.001mm ±4µm 275 - 300mm 293-257-30 0.001mm ±4µm Metric _ With ratchet thimble Range Model  Resolution Accuracy 0 - 25mm 293-234-30 / 293-244-30 0.001mm ±1µm 25 - 50mm 293-235-30 / 293-245-30 0.001mm ±1µm 50 - 75mm 293-236-30 / 293-246-30 0.001mm ±1µm 75 - 100mm 293-237-30 / 293-247-30  0.001mm ±2µm   read more
The Great Services added new photo in Height Gauge - Trimos
May 24, 2024 at 01:25 pm —
V7 Height Gauge

V7 Height Gauge

Specification Measuring ranges 400 to 1800 mm Simple and easy-to-use graphic interface Electronically adjustable measuring force Manual or motor-driven displacement 2d, programming, statistics Vast range of accessories All adjustments possible without tools RS232 et USB interfaces Wireless data transfer (optional)   V7 400 700 1100 1800 Measuring range mm (in) 407 (16) 711 (28) 1110 (44) 1810 (71) Measuring range with extension mm (in) 719 (28) 1023 (40) 1422 (56) 2122 (83) Max permissible errors, BMPE µm 2 + L(mm)/400 2.5 + L(mm)/300 Repeatability, RMPE (2s) µm 1 (Ø:2) Frontal squareness deviation SMPE µm 5 8 11 25 Max. Resolutions mm 0.0001 (0.00001) Measuring force N 0.75 ÷ 1.5 Autonomy h 12 Interfaces   USB / RS232 Air cushion   Yes Weight kg 22 25 34 41 read more
The Great Services added new photo
May 23, 2024 at 03:40 pm —
420 Digital External Dial Caliper Gauge

420 Digital External Dial Caliper Gauge

Specification  Measure the external dimension Resolution: 0.01mm/0.0005'' Code  Range  Accuracy L 420-020-11 0-20mm/0-0.8''    ±0.04mm 60 420-040-11 20-40mm/0.8-1.6'' ±0.04mm 60 420-060-11 40-60mm/1.6-2.4'' ±0.04mm 55 420-080-11 60-80mm/2.4-3.2'' ±0.04mm 55 420-100-11 80-100mm/3.2-4'' ±0.04mm 55   read more
The Great Services added new photo
May 23, 2024 at 02:51 pm —
 410 Digital Internal Dial Caliper Gauge

410 Digital Internal Dial Caliper Gauge

Specification  Measure the internal dimension Resolution: 0.01mm/0.0005'' Code  Range  Accuracy A B L 410-035-11 15-35mm/0.6-1.4'' ±0.04mm 3 Ø3 50 410-035-11L 15-35mm/0.6-1.4'' ±0.04mm 3 Ø3 200 410-055-11 35-55mm/1.4-2.2'' ±0.04mm 6 Ø3 80 410-055-11L 35-55mm/1.4-2.2'' ±0.04mm 6 Ø3 250 410-075-11 55-75mm/2.2-3'' ±0.04mm 8 Ø3 90 410-075-11L 55-75mm/2.2-3'' ±0.04mm 8 Ø3 250 410-095-11 75-95mm/3-3.8'' ±0.04mm 8 Ø3 100 410-095-11L 75-95mm/3-3.8'' ±0.04mm 8 Ø3 250 410-115-11 95-115mm/3.8-4.6'' ±0.04mm 10 Ø3.2 120 410-115-11L 95-115mm/3.8-4.6'' ±0.04mm 10 Ø3.2 250 410-135-11 115-135mm/4.6-5.4'' ±0.04mm 10 Ø3.2 120 410-135-11L 115-135mm/4.6-5.4'' ±0.04mm 10 Ø3.2 250   read more
The Great Services added new photo in Surface Roughness - Kosaka
May 21, 2024 at 04:46 pm —
SE800 Surface Roughness

SE800 Surface Roughness

Specification Z Max measuring range 600 µm X Max measuring range 100 mm Z Min resolution 0.04 nm Straightness 0.2 µm/100 mm Pick-up PU-DJ2S-60 Stylus R2 µm 60° Instellation size W1500 mm×D800 mm read more
The Great Services added new photo in Matsuzawa - MMT-X Series
May 21, 2024 at 01:51 pm —
MMT-X_Vickers_Hardnes_tester

MMT-X_Vickers_Hardnes_tester

Specification     MMT-X7                 MMT-X3 MMT-X1 Test force Standard Type A 49.03, 98.07, 245.2, 490.3, 980.7, 1961, 2942, 4903, 9807Mn    5         10        25       50      100      200     300    500    1000gf Option Type B 9.807, 29.42, 49.03, 98.07, 245.2, 490.3, 980.7, 1961, 2942, 4903, 9807, 19614mn 1         3          5        10          25       50      100      200    300    500    1000   2000 gf Loading mechanism Automatic loading and releasing method Indenter approach speed 50µm/sec Dwell time 5 ~ 99sec 5 ~ 30sec Indenter Standard : 1 (HV), Option : 2 (HV,HK) Objective lens Standard:2(40X,10X *in case of AMT-PS series : 40X,5X), Option : Max.4(5X~100X) Eyepiece lens Standard 10X  Option 15X Total magnification Standard (400X, 100X) Corresponding 50X ~ 1000X Measuring microscope (total 400X) Max. Measuring lenght 250µm Min. scale 0.01µm (200X ~ 1000X) 0.5µm Min. measuring 0.01µm (200X ~ 1000X) 0.01µm Type Electronic type Mechanical type Light source LED light source Turret Auto Manual LCD touch panel Color LCD touch panel - Testing mode 6 kinds of HV, HK, HBS, KC Xbar, Cylindrical correction - Data memory 999 data memory - Hardness conversion Possible in compliance with SAE(J-417B), ASTM(E-140) - OK/NG criteria Judging to the results by setting Max. and Min. - Statistical calculation Max.value, Min.value, Dispersion(R), Mean value, Converted value - Max. specimen height 120mm Max. specimen depht 160mm Data output Centronics (Dot printer output)   -    RS232C – (Output for PC), Possible to exhange to printer output - Accuracy According to JIS B7725 and ASTM E-384 Photo booth The photo booth can be installed in the body tube in the upper part of the main body at any time Dimentions and weight Main body only  W250XD520XH530mm 35kg Power suply Single phase AC100 ~ 240V 50/60Hz available for export models read more
The Great Services added new photo in Hardness Tester
May 15, 2024 at 02:28 pm —
VMT-X Series Vickers Hardnes Tester

VMT-X Series Vickers Hardnes Tester

Specification    VMT-X7 VMT-X3 VMT-X1 Test force - 9.807, 19.61, 29.42, 49.03, 98.07, 196.1, 294.2, 490.3    N    1         2         3         5       10       20      30      50      Kgf S 2.942, 4.903, 9.807, 29.42, 49.03, 98.07, 196.1, 294.2    N   0.3       0.5        1        3         5       10       20      30      Kgf Loading mechanism Automatic loading and releasing method Turret Automatic Manual Indenter approach 85µm/sec Dwell time 5 ~ 99sec 5 ~ 30sec Min. measuring unit 0.01µm (200X ~ 1000X), 0.02µm (100X) 0.01µm Objective lens - 10X S 10X, 20X 20X Eyepiece lens 10X Measuring microscope Max. measuring length 100X :999.9µm(200X:600.0 µm) Magnification 100X (200X) Measuring type Electronic Mechanical Data output 1. Centronics (standard) 2. RS232C - Output selectable RS232C or serial - Data memory Max 999 test data - Hardness conversion Possible in compliance with ASTM (E-140),JIS - OK/NG criteria Upper and lower limits setting and HI/OK/LOW display - Statistical calculation Data output and display: Max.value, Min.value, Dispersion(R), Mean value, Standard deviation. - RS232C communication line 1200/2400/4800/9600 bps Error detection, Parity select : even/non - Accuracy ISO 6507-2, JIS B7725, JIS B7734, ASTM E-384 Max specimen height 250m Max specimen depht 150mm Weight Test force standard type : about 55kg . S type : about 52kg Power suply Single phase AC100 ~ 240V 50/60Hz available for export models read more
The Great Services added new photo in Laizhou - Vickers hardness tester
May 14, 2024 at 11:07 am —
HV-1000A Automatic Turret Micro-Vickers Hardness Tester

HV-1000A Automatic Turret Micro-Vickers Hardness Tester

Details : Product Introduciton HV-1000A Micro hardness tester made of shell integral casting and processing, holes drilling and alignment with one operating, to ensure the concentricity and coaxiality of holes, that is a good foundation for the machine's high precision and high stability .The Hardness tester light source using a special high-quality imaging microscope light source system, light field brightness uniform and clear, thereby reducing the indentation measurement error. The user interface adopts the menu type humanized structure. You can select the hardness scale HV or HK for the hardness value, and input the display manually. Various hardness values can be converted to each other. Objective lens and indenter automatic conversion positioning, with the advantages of high efficiency and easy operation. The highlights of the new machine are as follows: The operating performance and function of the machine absolutely have the leading technology in the same industry. 1. The new machine adopts the new type of light source of the filter LED, the image is clear and does not hurt the eyes, and it is suitable for all kinds of products no exception, long life (can provide three years free replacement). 2. New machine RBI positioning using three-point positioning method, more accurate, repeat, the position no offset, . 3. New machine support shrapnel imported special custom materials with high toughness, high resistance to fatigue, not easy to deformation (can provide three years free replacement). 4. The new machine interface using user-friendly format, digital area and functional area distinction column, the face key is clearly marked with Chinese and English, at the same time menu with Chinese and English language switching display function, suitable for multi-national personnel operation. Menu function classification clear and meticulous, light brightness, menu selection and objective selection has a memory function. 5. 10X and 40X in the high profile models have both the measurement and observation function (similar to only 40X objective lens with a measurement function)     Specification Hardness Scale HV, HK Test Force 10-25-50-100-200-300-500-1000gf Hardness Range 1HV-3000HV Test Force Selection Manually Implementation of Standards EN-ISO6507、ASTM E384&E92 JIS Loading and Unloading Mode AUTO Dwelling Time 0-60s Adjustable Turret AUTO Micrometer Eyepiece Multiple 10X measure Resolution Ratio 0.25µm Drum Reading   Objective Magnificatio 10X 40X Total Magnification Times 100X (Observation)400X(Measurement) Measurement Range 150µm Optical Channel Dual Channel/CCD Filter Green Light Source Halogen Lamp(Brightness Adjustable) Hardness Resolution Ratio  0.1 Vickers Unit Hardness Conversion Brinell, Rockwell,Surface Rockwell Max. Height of Test Sample 90mm Centerline Depth 120mm XY Test Bench Size 100X100mm XY Test Bench Moving Distance 25X25mm XY Test Bench Min. Displacement Number 0.01mm Operating Temperature 23±5℃ Operating Humidity <65% Host Dimension 530mmX290mmX490mm Net Weight 40Kg Power Supply 220V 2A 50-60HZ read more
The Great Services added new photo in Laizhou - Vickers hardness tester
May 14, 2024 at 09:36 am —
HV-30A  Vickers Hardness Tester

HV-30A Vickers Hardness Tester

Details : Product Feature: This product in the mechanical, optical, light source on the use of unique, precise design, so that the indentation imaging more clear, more accurate measurement. The instrument adopts a closed-loop loading control system to improve the accuracy of the test force, and the repeatability and stability of the indication value are good. The new display screen LCD is used to display, and the hardness scale HV or HK can be selected on the operation panel. The tested hardness value can be converted to each other. It is equipped with two groups of objective lenses that can participate in the measurement, so that the measurement range is wider, the application range is wider, the operation is more intuitive and clearer, the test method, test force, indentation length, hardness value, test force holding time, date, time, hardness conversion value and other functions can be displayed on the screen, and it has a threaded interface for connecting digital cameras and CCD cameras, which is convenient to select computers and hardness analysis and measurement software. Application Range: Suitable for quenching, quenching and tempering, annealing, chilled castings, malleable castings, hard alloy steel, aluminum alloy, copper alloy, bearing steel and other hardness determination. Specification   Test force 0.3kgf, 0.5kgf , 1Kgf, 2Kgf, 2.5Kgf, 3Kgf, 5Kgf, 10Kgf, 20Kgf, 30Kgf Hardness measurement range 5HV~3000HV Test mode HV/HK Loading method Automatic(Loading/Maintain/Unloading) Objective lens and indenter conversion Automatic Convert scale HRA、HRB、HRC、HRD、HRF、HV、HK、HBW、HBS、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T Objective lens 10× (observation),20×(Measurement) Eyepiece 10× digital micrometer Dwelling time 1~60s Light source Halogen Max. height of specimen 175mm Distance from indenter to inner machine wall 125mm Max. height of specimen AC220V,50Hz Distance from indenter to inner machine wall ISO 6507,ASTM E384,JIS Z2244,GB/T 4340.2 Dimension 320*580*650mm Weight Net weight about 55kg   read more
next page